Tantalum-beads.net    
  - Your Source to information on tantalum beads

  Home

  About Us

  Production of Beads

  Suppliers of Beads

  Pricing

  Beads Literature

 

Literature on Tantalum Beads

Literature on Tantalum Beads yearly listing

 

 
 

Literature on Tantalum Beads alphabetic listing

Literature on Tantalum Beads yearly listing

Literature on Tantalum beads published in 2006:

……The experimental set-up consisted of a simulated model of an extra-articular Colles' fracture, including metallic beads inserted into the bone on either side of the fracture site……..

Literature on Tantalum beads published in 2005

….After percutaneous application of tantalum indicators for RSA, the intervertebral mobility was measured for the 3 most distal lumbar…..
  • Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty.

Literature on Tantalum beads published in 2004

Literature on Tantalum beads published in 2003

  • Insertion of tantalum beads in RSA of the hip.
….hip arthroplasty. It requires the insertion of tantalum beads into the bone permitting analysis of the radiographs. Extra-osseous beads….
…..The implant in the anterior part of the maxilla was a tantalum ball with a diameter….

Literature on Tantalum beads published in 2002

….implanted tantalum. When implanted as foil, wire, rod or ball there are several reports that tantalum can be….
  • The evolution of the study of the mechanics of running. Relationship to injury.

Literature on Tantalum beads published in 2001

Literature on Tantalum beads published in 1999

  • A standardized protocol for motion recordings of the shoulder.

Literature on Tantalum beads published in 1998

  • Tantalum ball position after total hip arthroplasty.
….operative placement of tantalum balls. We have reviewed the position and migration of these markers….

Literature on Tantalum beads published in 1997

  • Tantalum ball position after total hip Arthroplasty
….the operative placement of tantalum balls. We have reviewed the position and migration of these markers i….

Literature on Tantalum beads published in 1995

Literature on Tantalum beads published in 1992

Literature on Tantalum beads published in 1989

Literature on Tantalum beads published in 1987

Literature on Tantalum beads published in 1986

  • Mechanical Loosening of total Hip Implant Prostheses

Literature on Tantalum beads published in 1985

..tantalum markers was evaluated histologically. Reactions to pin markers (99.9% purity) and spherical markers….. The bioinertness of tantalum was reconfirmed as was its suitability for use as skeletal and soft tissue radiographic markers…..

Literature on Tantalum beads published in 1982

Literature on Tantalum beads published in 1977

 

Literature on Tantalum Beads alphabetic listing

Alberius P. Bone reactions to tantalum markers. A scanning electron microscopic study. Acta Anat(Basel) 1983;115(4):310-8.
Adalberth G, Nilsson KG, Byström S, Kolstad K, Mallmin H, Milbrink J. Stability assessment of a moderately conforming all-polyethylene tibial component in total knee arthroplasty: a prospective RSA study with 2 years of follow-up of the Kinemax Plus design. Am J Knee Surg. 1999 Fall;12(4):233-40.
Adalberth G, Nilsson KG, Byström S, Kolstad K, Milbrink J. All-polyethylene versus metal-backed and stemmed tibial components in cemented total knee arthroplasty. A prospective, randomised RSA study. J Bone Joint Surg Br. 2001 Aug;83(6):825-31.
Adalberth G, Nilsson KG, Byström S, Kolstad K, Milbrink J. Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty: prospective, randomised radiostereometric analysis study of the AGC total knee prosthesis. J Arthroplasty. 2000 Sep;15(6):783-92.
Adalberth G, Nilsson KG, Kärrholm J, Hassander H. Fixation of the tibial component using CMW-1 or Palacos bone cement with gentamicin: similar outcome in a randomized radiostereometric study of 51 total knee arthroplasties. Acta Orthop Scand. 2002 Oct;73(5):531-8.
Ahl T, Dalén N, Holmberg S, Selvik G. Early weight bearing of displaced ankle fractures. Acta Orthop Scand 1987;58(5):535-8.
Ahl T, Dalén N, Holmberg S, Selvik G. Early weight bearing of malleolar fractures. Acta Orthop Scand 1986;57(6):526-9.
Ahl T, Dalén N, Holmberg S, Selvik G. Early weight-bearing of displaced ankle fractures. Acta Orthop Scand. 1987;58:535-538.
Ahl T, Dalén N, Lundberg A, Selvik G. Mobility of the ankle mortise. A roentgenstereophotogrammetric analysis. Acta Orthop Scand 1987;58(4):401-2.
Alberius P, Malmberg M. Body weight gain as related to craniofacial and calvarial volumetric changes in growing rabbits. Anat Rec 1989;223(3):322-8.
Alberius P. Pattern of membranous and chondral bone growth. A roentgen stereophotogrammetric study in the rabbit. Acta Anat 1983;116:37-45
Albrektsson B E, Carlsson L V, Freeman M A, Herberts P, Ryd L. Proximally cemented versus uncemented Freeman-Samuelson knee arthroplasty. A prospective randomised study. J Bone Joint Surg 1992;74(2):233-8.
Albrektsson BEJ, Ryd L, Carlsson LV, Freeman MAR m fl. The effect of a stem on the tibial component of knee arthroplasty. A roentgen stereophotogrammetric study of uncemented tibial components in the Freeman-Samuelson knee arthroplasty. J Bone Joint Surg 1990;72-B:252-8.
Almquist PO, Arnbjörnsson A, Zätterstrom R, Ryd L, Ekdahl C, Friden T. Evaluation of an external device measuring knee joint rotation: an in vivo study with simultaneous Roentgen stereometric analysis.J Orthop Res. 2002 May;20(3):427-32.
Aronson A S, Hansson L I, Selvik G. Roentgen-stereophotogrammetry for determination of bone growth. Comparison with the tetracycline method. Acta Radiol (Diagn) (Stockh) 1977;18(1):87-93.
Aronson AS, Holst L, Selvik G. An instrument for insertion of radiopaque bone markers. Radiology1974;113:733-4.
Axelsson P, Johnsso R, Strömqvist B. Influence of lumbar orthrosis on intevertebral mobility. A roentgen stereophotogrammetric analysis. Spine 1992;17(6):678-81
Axelsson P, Johnsson R, Stromqvist B. Is there increased intervertebral mobility in isthmic adult spondylolisthesis? A matched comparative study using roentgen stereophotogrammetry. Spine. 2000 Jul 1;25(13):1701-3.
Axelsson P, Johnsson R, Strömqvist B, Arvidsson M, Herrlin K. Posterolateral lumbar fusion. Clinical and radiographic results of 71 consecutive operations. Acta Orthop Scand 1994;65(3):309-314.
Axelsson P, Johnsson R, Strömqvist B. Lumbar orthrosis with unilateral hip immobilization. Spine 1993;18(7):876-879
Axelsson P, Johnsson R, Strömqvist B. Mechanics of the external fixator test in the lumbar spine. A roentgen stereophotogrammetric analysis. Spine 1996;21(3):330-333.
Baldursson H, Egund N, Hansson L I, Selvik G. Instability and wear of total hip prostheses determined with roentgen-stereophotogrammetry. Arch Orthop Trauma Surg 1979;95(4):257-63.
Baldursson H, Hansson L I, Olsson T H, Selvik G. Migration of the acetabular socket after total hip replacement determined by roentgen-stereophotogrammetry. Acta Orthop Scand 1980;51(3):535-40.
Biedermann R, Stockl B, Krismer M, Mayrhofer P, Ornstein E, Franzen H. Evaluation of accuracy and precision of bone markers for the easurement of migration of hip prostheses. A comparison of conventional measurements. J Bone Joint Surg Br 2001 Jul;83(5):767-71
Blankevoort L, Huiskes R, De Lange A. Helical axes along the envelope of passive knee joint motion. Trans. Orthop. Res. New Orleans 1986:410.
Blankevoort L, Huiskes R, De Lange A. The envelope of passive knee joint motion. J Biomechanics 1988; 21:705-20.
Borssén B, Snorrason F, Önsten I, Kärrholm J. Revision hip arthroplasty using cemented acetabular cup and allografts. A roentgen stereophotogrammetric analysis (RSA). SOF Trollhättan 1991.Acta Orthop Scand 1991;62(Suppl 246):9.
Bragdon CR, Malchau H, Yuan X, Perinchief R, Kärrholm J, Börlin N, Estok DM,Harris WH.Experimental assessment of precision and accuracy of radiostereometric analysisfor thedetermination of polyethylene wear in a total hip replacement model. J Orthop Res. 2002 Jul;20(4):688-95.
Brandsson S, Karlsson J, Eriksson BI, Karrholm J. Kinematics after tear in the anterior cruciate ligament: dynamic bilateral radiostereometric studies in 11 patients. Acta Orthop Scand. 2001 Aug;72(4):372-8.
Brandsson S, Karlsson J, Sward L, Kartus J, Eriksson BI, Kärrholm J. Kinematics and laxity of the knee joint after anterior cruciate ligament reconstruction: pre- and postoperative radiostereometric studies. Am J Sports Med. 2002 May-Jun;30(3):361-7.
Bylander B, Aronson S, Egund N, Hansson L I, Selvik G. Growth disturbance after physial injury of distal femur and proximal tibia studied by roentgen-stereophotogrammetry. Arch Orthop Trauma Surg 1981;98(3):225-35.
Bylander B, Hagglund G, Selvik G. Dynamics of growth retardation after epiphysiodesis: a roentgen stereophotogrammetric analysis. Orthopedics. 1993 Jun;16(6):710-2.
Bylander B, Hansson L I, Selvik G. Pattern of growth retardation after Blount stapling: A roentgenstereophotogrammetric analysis. J Pediatr Orthop 1983;3(1):63-72.
Bylander B, Hansson LI, Kärrholm J, Naversten Y. Scintimetric evaluation of Post-traumatic and postoperative growth disturbance using 99TcmMDP. Acta Radiol Diagn 1983;24:85-96
Bylander B, Hägglund G, Selvik G. Stapling for tibial-growth deformity. A case report on roentgen stereophotogrammetric analysis. Acta Orthop Scand. 1989 Aug;60(4):487-90.
Bylander B, Selvik G, Hansson L I, Aronson S. A roentgen-stereophotogrammetric analysis of growth arrest by stapling. J Pediatr Orthop 1981;181):81-90.
Börlin N, Thien T, Karrholm J. The precision of radiostereometric measurements. Manual vs. digitalmeasurements.J Biomech. 2002 Jan;35(1):69-79.
Börlin N. High precision measurements in digital radiographs. Licentiate Thesis. Umeå University.Department of Computing Science. Umeå Sweden. Uminf 97.10. ISSN-0348-0542
Börlin N. Model-design measurements in digital radiographs. Thesis, Umeå, June 10, 2000.
Choo AM, Oxland TR. Improved RSA accuracy with DLT and balanced calibration marker distributions with an assessment of initial-calibration. J Biomech. 2003 Feb;36(2):259-64.
De Lange A, Huiskes R, Kauer JM. Measurement errors in roentgen-stereophotogrammetric jointmotion analysis. J Biomechanics 1990;23(3):259-69.
de Lange A, Kauer J M, Huiskes R. Kinematic behaviour of the human wrist joint: a roentgenstereophotogrammetric analysis. J Orthop Res 1985;3(1):56-64.
Ebbinghaus S, Mjöberg B. Posterior angulation in trochanteric fractures detected with roentgen stereophotogrammetry. Ups J Med Sci 1991;96(3):235-7.
Eberhardt K B, Selvik G. Some aspects of knee joint kinematics in rheumatoid arthritis as studied with roentgen-stereophotogrammetry. Clin Rheumatol 1986;5(2):201-9.
Edixhoven P H, Huiskes R, deGraaf R, vanRens Th J G, Sloot T J. Accuracy and reproducibility of instrumented knee-drawer tests. J Orthop Res. 1987;5:378-387.
Egund N, Olsson T H, Schmid H, Selvik G. Movements in the sacroiliac joints demonstrated with roentgen-stereophotogrammetry. Acta Radiol (Diagn) (Stockh) 1978;19(5):833-46.
Eldridge JDJ, Avramidis K, Lee M, Learmonth ID. Tantalum ball position after total hip arthroplasty. J Bone Joint Surg 1998;80-B: 414-16
Fleming BC, Peura GD, Abate JA, Beynnon BD. Accuracy and repeatability of Roentgen stereophotogrammetric analysis (RSA) for measuring knee laxity in longitudinal studies. J Biomech. 2001 Oct;34(10):1355-9.
Franzén H, Lidgren L, Toksvig-Larsen S, Önnerfält R. Early migration of femoral components revised with impacted cancellous allografts and cement. A preliminary report of five cases. J Bone Joint Surg (Br) 1995;77(6):862-864.
Franzén H, Mjöberg B. Wear and loosening of the hip prosthesis. A roentgen stereophotogrammetric 3-year study of 14 cases. Acta Orthop Scand 1990;61(6):499-501.
Franzén H, Mjöberg B., Önnerfält. Early migration of acetabular components revised with cement: A roentgen stereophotogrammetric study. Clin Orthop 1993; 287:131-4.
Fridén T, Ryd L, Lindstrand A. Laxity and graft fixation after reconstruction of the anterior cruciate ligament. A roentgen stereophotogrammetric analysis of 11 patients. Acta Orthop Scand 1992;63(1):80-4.
Fridén T, Sommerlat C, Egund N, Gillquist J, Ryd L,Lindstrand A. Measured laxity of the knee. Measurements of sagittal laxity compared in 11 cases. Acta Orthop Scand 1992;63(6):593-598.
Gottholdson Lawin P, Rye-Danjelsen G, Skarström M. Tredimensionell datorstudie av knäledsrörelsemönster. Tekniska högskolan i Lund, Lund, Sweden. Report TVSM-5045, ISSN 0281-6679, 1992.
Gunnarsson G, Axelsson P, Johnsson R, Stromqvist B. A method to evaluate the in vivo behaviour of lumbar spine implants. Eur Spine J. 2000 Jun;9(3):230-4.
Hansson L I, Olsson T H, Selvik G, Sundén G. A roentgen-stereophotogrammetric investigation of innominate osteotomy (Salter). Acta Orthop Scand 1978;49(1):68-72.
Hildebrand H, Aronson S, Kullendorff CM, Selvik G. Roentgen stereophotogrammetric short-term analysis of growth rate in children operated for Crohn's disease. Acta Paediatr Scand. 1991 Oct;80(10):917-23.
Hildebrand H, Aronson S, Selvik G. Growth as a parameter of inflammation in Crohn's disease, using roentgen stereophotogrammetric analysis. Acta Paediatr. 1994 Oct;83(10):1070-5.
Hilding M, Lanshammar H, Ryd L. Knee joint load and tibial component loosening. Roentgen stereophotogrammetry and gait analysis in 45 osteoarthrosis patients before and after total knee arthroplasty. J Bone Joint Surg, 1996 ;78-B(1):66-73.
Hilding M, Ryd L, Toksvig-Larsen S, Aspenberg P. Clodronate prevents prosthetic migration: a randomized radiostereometric study of 50 total knee patients. Acta Orthop Scand. 2000 Dec;71(6):553-7.
Hilding M, Yuan X, Ryd L. The stability of three different cementless tibial components. A randomized radiostereomethric study in 45 knee arthroplasty patients. Acta Orthop Scand, 1995;66(1):21-27.
Hilding MB, Ryd L, Toksvig-Larsen S, Mann A, Stenstrom A. Gait affects tibial component fixation. J Arthroplasty. 1999 Aug; 14(5):589-93.
Huiskes R, Verdonschot N, Nivbrant B. Migration stem shape and surface finish in cemented total hip arthroplasty. Clin Orthop. 1998 Oct;(355):103-12.
Hyldahl HC, Regner L, Carlsson L, Karrholm J, Weidenhielm L. Does metal backing improve fixation of tibial component in unicondylar knee arthroplasty? A randomized radiostereometric analysis. J Arthroplasty 2001 Feb;16(2):174-9
Hägglund G, Bylander B, Hansson L I, Selvik G. Bone growth after fixing slipped femoral epiphyses: brief report. J Bone Joint Surg (Br) 1988;70(5):845-6.
Hägglund G, Bylander B, Hansson LI, Kärrholm J, Selvik G, Svensson K. Longitudinal growth of the distal fibula in children with slipped capital femoral epiphysis. J Pediatr Orthop 1986;6:274-7
Ilchmann T, Franzén H, Mjöberg B, Wingstrand H. Measurement accuracy in acetabular cup migration: A comparison of four radiographic methods versus roentgen stereophotogrammetric analysis. J Arthroplasty 1992;7(2):121-128.
Johnsson R, Axelsson P, Gunnarsson G, Stromqvist B Stability of lumbar fusion with transpedicular fixation determined by roentgen stereophotogrammetric analysis. .Spine 1999 Apr 1;24(7):687-90
Johnsson R, Selvik G, Strömqvist B, Sundén G. Mobility of the lower lumbar spine after posterolateral fusion determined by roentgen stereophotogrammetric analysis. Spine 1990;15(5):347-350.
Johnsson R, Strömqvist B, Aspenberg P. Randomized radiostereometric study comparing osteogenic protein-1 (BMP-7) and autograft bone in human noninstrumented posterolateral lumbar fusion: 2002 Volvo Award in clinical studies Spine. 2002 Dec 1;27(23):2654-61.
Johnsson R, Strömqvist B, Axelsson P, Selvik G: Influence of spinal immobilization on consolidation of posterolateral lumbosacral fusion. Spine 1992;17(1):16-21.
Jonsson H, Elmqvist L-G, Kärrholm J, Fugl-Meyer A. Lengthening of anterior cruciate ligament graft. Roentgen stereophotogrammetry of 32 cases 2 years after repair. Acta Orthop Scand. 1992;63 (6):587-592.
Jonsson H, Elmqvist LG, Kärrholm J, Tegner Y. Over-the top or tunnel reconstruction of the anterior cruciate ligament. A prospective randomised study of 54 cases. J Bone Joint Surg (Br) 1994;76- B:82-7.
Jonsson H, Kärrholm J, Elmqvist LG. Kinematics of active knee extension after tear of the anterior cruciate ligament. Am J Sports Med 1989;17(6):796-802
Jonsson H, Kärrholm J, Elmqvist L-G. Measurement of knee laxity. Comparison between KT-1000 and roentgen stereophotogrammtry. Acta Orthop Scand. 1993;64:567-70.
Jonsson H, Kärrholm J. Brace effects on the unstable knee in 21 cases. A roentgen stereophotogrammetric comparison of three designs. Acta Orthop Scand 1990;(61):313-318
Jonsson H, Kärrholm J. Three-dimensional knee joint movements during a step-up. Evaluation after anterior cruciate ligament rupture. J Orthop Res. 1994;12:769-79
Jonsson H, Kärrholm J. Three-dimensional knee kinematics and stability in patients with a posterior cruciate ligament tear. J Orthop Res. J Orthop. Res. 1999;17(2):185-91ax
Jorn LP, Fridén T, Ryd L, Lindstrand A. Simultaneous measurements of sagittal knee laxity with an external device and radiostereometric analysis. J Bone Joint Surg (Br) 1998;80-B:169-172.
Kopylov P, Aspenberg P, Yuan X, Ryd L. Radiostereometric analysis of distal radial fracture displacement during treatment: a randomized study comparing Norian SRS and external fixation in 23 patients. Acta Orthop Scand. 2001 Feb;72(1):57-61.
Kärrholm J, Anderberg C, Snorrason F, Thanner J, Langeland N, Malchau H,Herberts P. Evaluation of a femoral stem with reduced stiffness. A randomized study with use of radiostereometry and bone densitometry.J Bone Joint Surg Am. 2002 Sep;84-A(9):1651-8.
Kärrholm J, Borssén B, Löwenhielm G, Snorrason F. Do early micromotions of femoral stem prostheses matter? Stereoradiographic 5-8 year follow-up of 84 cemented hip prostheses. J BoneJoint Surg (Br) 1994;76-B(6):912-917.
Kärrholm J, Brandsson S, Freeman MA. Tibiofemoral movement 4: changes of axial tibial rotation caused by forced rotation at the weight-bearing knee studied by RSA. J Bone Joint Surg Br. 2000 Nov;82(8):1201-3.
Kärrholm J, Elmqvist LG, Hansson LI, Selvik G. Chronic anterolateral instability of the knee. A roentgen stereophotogrammetric evaluation. Am J Sports Med 1989;17(4):555-563.
Kärrholm J, Frech W, Nilsson KG, Snorrason F. Increased Metal release from Cemented femoral components made of titanium alloy. Evaluation of 19 Hip Prostheses Followed with Stereoradiography. Acta Othop Scand . 1994;65(6):599-604
Kärrholm J, Frech W, Nivbrant B, Malchau H, Snorrason F, Herberts P. Fixation and metal release from the Tifit femoral stem prosthesis. 5 year follow-up of 64 cases. Acta Orthop Scand. 1998;69(4):369-378
Kärrholm J, Hansson LI, Laurin S, Selvik G. Post-traumatic growth disturbance of the ankle treated by the Langenskiöld procedure. Evaluation by radiology, roentgen stereophotogrammetry, scintimetry and histology. Case report. Acta Orthop Scand 1983;54:721-9
Kärrholm J, Hansson LI, Laurin S, Selvik G. Roentgen stereophotogrammetric study of fracture through tibial shaft ankle and heel. Arch Orthop Traumat Surg 1982;99:253-258.
Kärrholm J, Hansson LI, Selvik G. Changes in tibiofibular relationships due to growth disturbances after ankle fractures in children. J Bone Joint Surg (Am) 1984;66:1198-210
Kärrholm J, Hansson LI, Selvik G. Longitudinal growth rate of the distal tibia and fibula in children. Clin Orthop 1984;191:121-8
Kärrholm J, Hansson LI, Selvik G. Mobility of the lateral malleolus. A roentgen stereophotogrammetric analysis. Acta Orthop Scand 1985;56(6):479-83
Kärrholm J, Hansson LI, Selvik G. Roentgen stereo-photogrammetric analysis of growth pattern after pronation ankle injuries in children. Acta Orthop Scand 1982;53:1001-11
Kärrholm J, Hansson LI, Selvik G. Roentgen stereo-photogrammetric analysis of growth pattern after supination-adduction ankle injuries in children. J Pediatr Orthop 1982;2:271-9
Kärrholm J, Hansson LI, Selvik G. Roentgen stereo-photogrammetric analysis of growth pattern after supination-eversion ankle fractures in children. J Pediatr Orthop 1982;2:25-37
Kärrholm J, Hansson LI, Svensson, K. Prediction of growth pattern after ankle fractures in children. J Pediatr Orthop 1983;3:319-325
Kärrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J. Radiostereometry of Hip rostheses. Review of Methodology and Clinical Results. Clin Orthop; 344: 94-110.
Kärrholm J, Hultmark P, Carlsson L, Malchau H. Subsidence of a non-polished stem in revisions of the hip using impaction allograft. Evaluation with radiostereometry and dual energy x-ray absorptiometry. Journal of Bone and Joint Surgery, 1999;81-B(1):135-142
Kärrholm J, Jonsson H, Nilsson KG, Söderqvist I. Kinematics of succesful knee prostheses during weight-bearing. Knee Surgery Sports Traumatology Arthroscopy. 1994;2:50-9.
Kärrholm J, Malchau H, Snorrason F, Herberts P. Femoral component fixation in total hip arthroplasty. Evaluation of contemporary cementing technique, porous and hydroxyapatite coatings using roentgen stereophotogrammetric analysis. Trans. 38th Annual Meeting of Orthopaedic Research Society. p.291 Washington 1992.
Kärrholm J, Malchau H, Snorrason F, Herberts P. Micromotion of cemented, hydroxyapatite and porous coated femoral stems. Randomised study using roentgen stereophotogrammetric analysis. J Bone Joint Surg (Am) 1994;76-A(11):1691-1705.
Kärrholm J, Selvik G, Elmqvist L-G, Hansson LI, Jonsson H. Three-dimensional instability of the anterior cruciate deficient knee. J Bone Joint Surg (Br) 1988:70;777-83
Kärrholm J, Selvik G, Elmqvist LG. Active knee motion after cruciate ligament rupture. Stereoradiography. Acta Orthop Scand 1988;59(2):158-64
Kärrholm J, Snorrason F. Migration of porous coated acetabular prostheses fixed with screws. J Orthop Res. 1992;10:826-835.
Kärrholm J, Snorrason F. Subsidence, tip and hump micromovements of non-coted ribbed femoral prostheses. Clin Orthop 1993;287:50-60.
Kärrholm J. Roentgen stereophotogrammetry. Review of orthopaedic applications. Acta Orthop Scand 1989;60(4):491-503
Lawrie David F M, Downing Martin R, Ashcroft G Patrick, Gibson Peter H. Insertion of tantalum beads in RSA of the hip. Variations in incidence of extra-osseous beads with insertion site. Acta Orthop Scand 2003;74(4):404-407.
Leardini A, Cappozzo A, Catani F, et al.. Validation of a functional method for the estimation of hip joint centre location. J Biomech 1999 Jan;32(1):99-103
Leivseth G, Brinckmann P, Frobin W, Johnsson R, Stromqvist B. Assessment of sagittal plane segmental motion in the lumbar spine. A comparison between distortion-compensated and stereophotogrammetric roentgen analysis. Spine 1998 Dec 1;23(23):2648-55
Li MG, Nilsson KG. No relationship between postoperative changes in bone density at the proximal tibia and the migration of the tibial component 2 years after total knee arthroplasty. J Arthroplasty. 2001 Oct;16(7):893-900.
Li MG, Nilsson KG. The effect of the preoperative bone quality on the fixation of the tibial component in total knee arthroplasty.J Arthroplasty. 2000 Sep;15(6):744-53.
Lundberg A, Svensson O K, Németh G, Selvik G. The axis of rotation of the ankle joint. J Bone Joint Surg (Br) 1989;7(1):94-9.
Lundberg A. Kinematics of the ankle and foot. In vivo roentgen stereophotogrammetry. Acta Orthop Scand Suppl 1989;233:1-24.
Löfvenberg R, Kärrholm J, Ahlgren O. Ankle stability in patients operated for chronic lateral instability. Five year follow-up study using roentgen stereophotogrammetric analysis. Acta Orthop Scand. 1994;65(4):401-407.
Löfvenberg R, Kärrholm J, Lundberg A. Subtalar stability in chronic lateral instability of the ankle. The Foot. 1992;2:39-43.
Löfvenberg R, Kärrholm J, Lundberg A. Subtalar stability in chronic lateral instability of the ankle. The Foot. 1992;2:39-43.
Löfvenberg R, Kärrholm J, Selvik G, Hansson LI, Ahlgren O. Chronic lateral instability of the talocrural joint. Acta Orthop Scand 1989;60(1):34-9
Löfvenberg R, Kärrholm J, Selvik G. Fibular mobility in chronic lateral instability of the ankle. J Foot & Ankle 1990;11(1):22-29.
Löfvenberg R, Kärrholm J. The influence of an ankle orthosis on the talar and calcaneal motions in chronic lateral instability of the ankle. Am J Sports Med.. 1993;21(2):224-30.
Magyar O, Toksvig-Larsen S, Lindstrand A. Changes in osseous correction after proximal tibial osteotomy: radiostereometry of closed- and open-wedge osteotomy in 33 patients. Acta Orthop Scand. 1999 Oct;70(5):473-7.
Malchau H, Kärrholm J, Wang YX, Herberts P. Accuracy of migration analysis in total hip arthroplasty. Digitised and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand 1995;66(5):418-24.
Mjöberg B The theory of early loosening of hip prostheses. Orthopedics 1997 Dec;20(12):1169-75
Mjöberg B, Brismar J, Hansson L I, Pettersson H, Selvik G, Önnerfält R. Definition of endoprosthetic loosening. Comparison of arthrography, scintigraphy and roentgen-stereophotogrammetry in prosthetic hips. Acta Orthop Scand 1985;56(6):469-73.
Mjöberg B, Hansson L I, Selvik G. Instability, migration and laxity of total hip prostheses. A roentgen stereophotogrammetric study. Acta Orthop Scand. 1984;55:141-145.
Mjöberg B. Fixation and loosening of hip prostheses. A review: see comments. Acta Orthop Scand 1991;62(5):500-8.
Mjöberg B. Loosening of the cemented hip prosthesis. The importance of heat injury. Acta Orthop Scand 1986;57(Suppl 221):1-40.
Mogensen B, Ekelund L, Hansson L I, Lidgren L, Selvik G. Surface replacement of the hip in chronic arthritis. A clinical, radiographic and roentgen-stereophotogrammetric evaluation. Acta Orthop Scand 1982;53(6):929-36.
Nilsson K G, Kärrholm J, Ekelund L, Magnusson P. Evaluation of micromotion in cemented vs uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis. Randomised study using roentgen stereophotogrammetric analysis. J Arthroplasty 1991:6(3):265-278
Nilsson KG, Brobäck LG, Kärrholm J. Does a stem on the tibial component improve fixation of uncemented Freeman-Samuelson knee prosthesis. SOF Sundsvall. Acta Orthop Scand 1989;60(Suppl):34
Nilsson KG, Cajander S, Kärrholm J. Early failure of hydroxyapatite-coating in total hip arthroplasty. Case report. Acta Orthop Scand. 1994;65(2):212-14.
Nilsson KG, Cajander S, Kärrholm J. Early failure of hydroxyapatite-coating in total hip arthroplasty. Case report. Acta Orthop Scand. 1994;65(2):212-14. (see also below)
Nilsson KG, Hietala S-O, Björnebrink J, Kärrholm J. Scintimetry after total knee arthroplasty: Prospective 2-year study of 18 cases of arthrosis and 15 cases of rheumatoid arthritis. Acta Orthop Scand 1992;63(2):159-165.
Nilsson KG, Kärrholm J, Carlsson L, Dalén T. Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty. Prospective randomized comparison of hydroxyapatite-coated and cemented tibial components with 5-year follow-up using radiostereometry. J of Arthroplasty 1999;14(1):9-20.
Nilsson KG, Kärrholm J, Ekelund L. Active knee motion in total knee arthroplasty. A roentgen stereophotogrammetric analysis of the kinematics of the Tricon-M knee prosthesis. Clin Orthop 1990;256:147-161.
Nilsson KG, Kärrholm J, Gadegaard P. Abnormal kinematics of the artificial knee. Roentgen stereophotogrammetric analysis of 10 Miller-Galante and 5 New Jersey LCS knees. Acta Orthop Scand 1991;62(5):440-446.
Nilsson KG, Kärrholm J, Linder L. Micromotion of the femoral component in Miller-Galante knee arthroplasty. Cemented vs. cementless fixation. J Orthop Res.1995;13:347-56
Nilsson KG, Kärrholm J, Linder L. Micromotion of the femoral component in Miller-Galante knee arthroplasty. Cemented vs. cementless fixation. J Orthop Res.1995;13:347-56.
Nilsson KG, Kärrholm J. Increased subsidence of stemmed cementless Tricon-M knee prostheses. Roentgen stereophotogrammetric analysis of cemented vs uncemented tibial components. Am J Knee Surg 1992;5(4):174-183
Nilsson KG, Kärrholm J. Increased varus-valgus tilt of screw-fixated knee prostheses. Roentgen stereophotogrammetric study of cemented vs. cementless tibial components. J Arthroplasty. 1993;8(5):529-540.
Nilsson KG, Kärrholm J. RSA in the assessment of aseptic loosening. Editorial. J Bone Joint Surg (Br). 1996;78-B(1):1-3
Nistor L, Blaha D, Källström U, Selvik G. Roentgen-stereophotogrammetric analysis RSA of the LMPCH prosthesis. Acta Orthop Scand 1987;58(4):445.
Nistor L, Blaha JD, Kjellström U, Selvik G. In vivo measurements of relative motion between an uncemented femoral total hip component and the femur by roentgen sterephotogrammetric analysis. Clin Orthop 1991;269:220-227
Nivbrant B, Karlsson K, Kärrholm J. Cytokine levels in synovial fluid from hips with wellfunctioning or loose prostheses. J Bone Joint Surg Br. 1999 Jan;S 1(1): 163-6.
Nivbrant B, Kärrholm J, Röhrl S, Hassander H, Wesslen B. Bone cement with reduced proportion of monomer in total hip arthroplasty: preclinical evaluation and randomized study of 47 cases with 5 years' follow-up. Acta Orthop Scand. 2001 Dec;72(6):572-84.
Nivbrant B, Kärrholm J, Söderlund P. Increased migration of the SHP prosthesis: radiostereometric comparison with the Lubinus SP2 design in 40 cases. Acta Orthop Scand. 1999 Dec;70(6):569-77.
Nivbrant B, Kärrholm J, Önsten I, Carlsson Å, Snorrason F. Migration of porous press-fit cups in hip revision arthroplasty. A radiostereometric 2 year follow up study of 60 hips. J Arthroplasy, 1996;11(4):390-396.
Nivbrant B, Kärrholm J. Migration and wear of hydroxyapatite-coated press-fit cups in revision hip arthroplasty. A radiostereometric study. J Arthroplasty 1997;12(8):904-912.
Nyström L, Söderqvist I, Wedin P-Å. A note on some identification problems arising in roenytgen streophotogrammetric analysis. Technical Note. J Biomechanics 1994;27(10):1291-4.
Nyström L. Algorithms and Program system for Roentgen Stereophotogrammetric Analysis. Licentiate of Philosophy. Institute of Information Processing. Department of Computer Science. University of Umeå. UMINF - 187.90. ISSN-0348-0542, 1990.
Olsson T H, Selvik G, Willner S. Kinematic analysis of posterolateral fusion in the lumbosacral spine. Acta Radiol (Diagn) (Stockh) 1976;17(49:519-30.
Olsson T H, Selvik G, Willner S. Mobility in the lumbosacral spine after fusion studied with the aid of roentgen-stereophotogrammetry. Clin Orthop 1977;(129):181-90.
Olsson T H, Selvik G, Willner S. Vertebral motion in spondylolisthesis. Acta Radiol (Diagn) (Stockh) 1976;17(6):861-8.
Olsson T H, Selvik G. Willner S. Postoperative kinematics in structural scoliosis. Acta Radiol (Diagn) (Stockh) 1977;18(1):75-86.
Ornstein E, Atroshi I, Franzen H, Johnsson R, Sandquist P, Sundberg M. Early complications after one hundred and forty-four consecutive hip revisions with impacted morselized allograft bone and cement.J Bone Joint Surg Am. 2002 Aug;84-A(8):1323-8.
Ornstein E, Atroshi I, Franzen H, Johnsson R, Sandquist P, Sundberg M. Results of hip revision using the Exeter stem, impacted allograft bone, and cement. Clin Orthop. 2001 Aug;(389):126-33.
Ornstein E, Franzen H, Johnsson R, Stefansdottir A, Sundberg M, Tagil M. Hip revision with impacted morselized allografts: unrestricted weight-bearing and restricted weight-bearing have similar effect on migration A radiostereometry analysis. Arch Orthop Trauma Surg. 2003 Jul;123(6):261-7
Ornstein E, Franzen H, Johnsson R, Sundberg M. Radiostereometric analysis in hip revision surgery- optimal time for index examination: 6 patients revised with impacted allografts and cement followed weekly for 6 weeks. Acta Orthop Scand. 2000 Aug;71(4):360-4.
Ornstein E. Hip revisions with impacted morselized allograft bone and cement. Patient outcome, prosthetic fixation and risks. Acta Orthop Scand Suppl. 2002 Dec;73(306):1-66. No abstract available.
Pape D, Adam F, Fritsch E, Muller K, Kohn D. Primary lumbosacral stability after open posterior and endoscopic anterior fusion with interbody implants: a roentgen stereophotogrammetric analysis. Spine. 2000 Oct 1;25(19):2514-8.
Pape D, Fritsch E, Kelm J, Muller K, Georg T, Kohn D, Adam F. Lumbosacral stability of consolidated anteroposterior fusion after instrumentation removal determined by roentgen stereophotogrammetric analysis and direct surgical exploration. Spine. 2002 Feb 1;27(3):269-74.
Ragnarsson JI, Boquist L, Ekelund L, Kärrholm J. Instability and femoral head vitality in fractures of the femoral neck. Roentgen stereophotogrammetric analysis and low field magnetic resonance imaging with correlation to histopathology. Clin Orthop 1993;287:30-
Ragnarsson JI, Boquist L, Ekelund L, Kärrholm J. Instability and femoral head vitality in fractures of the femoral neck. Roentgen stereophotogrammetric analysis and low field magnetic resonance imaging with correlation to histopathology. Clin Orthop In press.
Ragnarsson JI, Eliasson P, Kärrholm J, Lundström B. The accuracy of measurements of femoral neck fracture; Conventional radiography versus roentgen stereophotogrammetric analysis. Acta Orthop Scand. 1992;63(2):152-156.
Ragnarsson JI, Eliasson P, Kärrholm J, Lundström B. The accuracy of measurements of femoral neck fracture; Conventional radiography versus roentgen stereophotogrammetric analysis. Acta Orthop Scand. 1992;63(2):152-156.
Ragnarsson JI, Hansson LI, Kärrholm J. Stability of femoral neck fractures. A postoperative roentgen stereophotogrammetric analysis. Acta Orthop Scand 1989;60(3):283-287
Ragnarsson JI, Kärrholm J. Factors influencing postoperative movements in displaced femoral neck fractures: Evaluation by conventional and stereoradiography (RSA). J Orthop Trauma 1992;6:152-8.
Ragnarsson JI, Kärrholm J. Factors influencing postoperative movements in displaced femoral neck fractures: Evaluation by conventional and stereoradiography (RSA). J Orthop Trauma. 1992;6(2):152-8.
Ragnarsson JI. Appendix in: Stability of Femoral Neck Fractures. Evaluation with Roentgen Stereophotogrammetric Analysis, Magnetic Resonance Imaging, Scintimetry, Radiography and Histopathology. Thesis. Umeå 1991.
Ragnarsson JI. Kärrholm J. Stability of femoral neck fracture: Roentgen stereophotogrammetry of 29 hook-pinned fractures. Acta Orthop Scand 1991;62(3):201-207
Regner L, Carlsson L, Karrholm J, Herberts P. Ceramic coating improves tibial component fixation in total knee arthroplasty. J Arthroplasty 1998 Dec;13(8):882-9
Regner L, Carlsson L, Karrholm J, Herberts P. Tibial component fixation in porous- and hydroxyapatite-coated total knee arthroplasty: a radiostereo metric evaluation of migration and inducible displacement after 5 years. J Arthroplasty 2000 Sep;15(6):681-9
Regnér LR, Carlsson LV, Kärrholm JN, Hansson TH, Herberts PG, Swanpalmer J. Bone mineral and migratory patterns in uncemented total knee arthroplasties: a randomized 5-year follow-up study of 38 knees. Acta Orthop Scand. 1999 Dec;70(6):603-8.
Resch S, Stenström A, Ryd L, Xunhua Yang. Measurement of the forefoot with roentgen stereophotogrammetry in hallux valgus surgery. Foot & Ankle 1995;16(5):271-276.
Rune B, Sarnas KV, Aberg M. Mandibulofacial dysostosis--variability in facial morphology and growth: a long-term profile roentgenographic and roentgen stereometric analysis of three patients.
Rune B, Sarnäs K V, Selvik G, Jacobsson S. Roentgen-sterephotogrammetry in the study of carniofacial anomalies-the state of the art in Sweden. Br J Orthod 1986;13(3):151-7.
Rune B, Sarnäs KV, Selvik G, Jacobsson S. Roentgen stereophotogrammetry in the study of craniofacial anomalies - the state of the art in Sweden. Br J Orthod 1986;13(3):151-7
Rune B, Sarnäs KV, Selvik G. Jacobsson S. Movement of the cleft maxilla in infants relative to the frontal bone. A roentgen stereophotogrammetric study with the aid of metal implants. Cleft Palate J 1980;17(2):155-74
Rune B, Selvik G, Kreiborg S, Sarnäs K V, Kågström E. Motion of bones and volume changes in the neurocranium after craniectomy in Crouzon´s disease. A roentgen-stereophotogrammetric study. J Neurosurg 1979;50(4):494-8.
Rune B. Roentgen-stereophotogrammetry and metallic implants in the study of craniofacial anomalies. Thesis. University of Lund, Malmö, Sweden 1980
Ryd L, Albrektsson BEJ, Carlsson L, Herberts P, Lindstrand A, Regnér L, Dansgaard F, Toksvig- Larsen S. Roentgenstereophotogrammetric Analysis (RSA) as a predictor of mechanical loosening. J Bone Joint Surg,1995;77-B(3):377-383
Ryd L, Albrektsson BEJ, Herberts P, Lindstrand A, Selvik G. Micromotion of non-cemented Freeman-Samuelson knee prostheses in Gonarthrosis. A roentgen stereophotogrammetric analysis of eight successful cases. Clin Orthop 1988;229:205-212
Ryd L, Boegård T, Egund N, Lindstrand A, Selvik G, Thorngren K G. Migration of the tibial component in successful unicompartmental knee arthroplasty. A clinical, radiographic and roentgen-stereophotogrammetric study. Acta Orthop Scand 1983;54(3):408-16.
Ryd L, Carlsson L, Herberts P,. Micromotion of the MILLER-GALANTE tibial component. An invivo roentgen stereophotogrammetric study. Clin Orthop, 1993;295:218-225
Ryd L, Gustafson T, Lindstrand A. Tc99-diphosphonate scienttimetry in successful knee arthroplasty and its relation to micromotion. Clin Orthop 1993;b287:61-67
Ryd L, Hansson U, Blunn G, Lindstrand A, Toksvig-Larsen. Failure of partial cementation to achieve implant stability and bone ingrowth: a long-term roentgen stereophotogrammetric study of tibial components. J Orthop Res 1999 May;17(3):311-20
Ryd L, Linder L. On the correlation between micromotion and histology of the bone-cement interface. Report of three cases of knee arthroplasty followed by roentgen stereophotogrammetric analysis. J Arthroplasty 1989;4(4):303-9.
Ryd L, Lindstrand A, Rosenquist R, Selvik G. Tibial component fixation in knee arthroplasty. An in vivo roentgen stereophotogrammetric study of cemented metal backed devices. Clin Orthop. 1986;213:141-149.
Ryd L, Lindstrand A, Stenström A, Selvik G. Cold-flow of unicompartmental tibial components. Acta Orthop Scand 1990a;61(1):21-25
Ryd L, Lindstrand A, Stenström A, Selvik G. PCA tricompartmental tibial components: relation between position and micromotion. Clin Orthop. 1990;251:189-197.
Ryd L, Lindstrrand A, Rosenquist R, Selvik G. Micromotion of all-polyethylene prosthetic components in total knee replacements. A stereophotogrammetric analysis of migration and inducible displacements. Arch Orthop Trauma Surg 1987a;106:82-88
Ryd L, Toksvig-Larsen. Early postoperative fixation of tibial components: An in vivo roentgen stereophotogrammetric analysis. J. Orthop. Res 1993;11:142-8.
Ryd L, Toksvig-Larsen. Stability of the elevated fragment in tibial plateau fractures. A roentgen stereophotogrammetric stufy of postoperative healing. Int Orthopedics 1994;18:131-4.
Ryd L, Yuan X, Löfgren H. Methods for determining the accuracy of radiostereometric analysis (RSA). Acta Orthop Scand. 2000 Aug;71(4):403-8.
Ryd L,, Egund N. Subsidence of tibial components in knee arthroplasty. A comparison between conventional radiography and roentgen stereophotogrammetry. Invest Radiol 1995;30(4):396-400
Ryd L. Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of tibial component fixation. Acta Orthop Scand 1986;57(Suppl 220):1-80.
Ryd L. Roentgen stereophotogrammetric analysis of prosthetic fixation in the hip and knee joint. Clin Orthop 1992;(276):56-65.
Ryd L. Roentgen Stereophotogrammetric analysis of prosthetic fixation in the hip and knee joint. Clin Ortop 1992;(276):56-65
Ryd L. The role of roentgen stereophotogrammetric analysis (RSA) in knee surgery. AM J Knee Surg. 1992;5(1):44-54.
Sarnas KV, Rune B, Aberg M. Facial growth in a cleft palate patient treated with the Herbst appliance: a long-term profile roentgenographic and roentgen stereometric analysis of profile changes and displacement of the jaws. Cleft Palate Craniofac J. 2000 Jan;37(1):71-7.
Selvik G, Alberius P, Fahlman M. Roentgen-stereophotogrammetry for analysis of cranial growth. Am J Orthod 1986;89(4):315-25.
Selvik G, Alberius P., Aronson A.S.: A roentgen stereophotogrammetric system. Construction, calibration and technical accuracy. Acta Radiol (Diagn) 1983;24:343-352.
Selvik G. Roentgen stereophotogrammetric analysis. Acta Radiol 1990;31(2):113-26.
Selvik G. Roentgen Stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Thesis, University of Lund, Lund, Sweden 1974. Reprint: Acta Orthop Scand 1989;Suppl 232.
Selvik G. Roentgen-stereophotogrammetry in Lund, Sweden. In: proc SPIE 1978;166:184-90.
Selvik G. Roentgen-stereophotogrammetry in orthopaedics. In: Biostereometrics '82. (Ed. Herron R
Snorrason F, Kärrholm J, Holmgren C. Fixation of cemented acetabular prostheses. J Arthroplasty 1993;8:83-93.
Snorrason F, Kärrholm J. Primary migration of fully-threaded acetabular prostheses. J Bone Joint Surg (Br) 1990;72(4):647-652.
Snorrason F, Kärrholm J. Roentgen stereophotogrammetric analysis (RSA) of acetabular prostheses. Scientific Exhibit. American Academy of Orthopaedic Surgeons. 57th Annual Meeting. New Orleans, 1990.
Snorrason F. Kärrholm J. Primary stability of revision total hip arthroplasty: A roentgen stereophotogrammetric analysis. J Arthroplasty 1990;5:217-229.
Soavi R, Girolami M, Loreti I, Bragonzoni L, Monti C, Visani A, Marcacci M. The mobility of the proximal tibio-fibular joint. A Roentgen Stereophotogrammetric Analysis on six cadaver specimens. Foot Ankle Int. 2000 Apr;21(4):336-42.
Soavi R, Motta M, Visani A. Variation of the spatial position computed by Roentgen Stereophotogrammetric Analysis (RSA) under non-standard conditions. Med Eng Phys. 1999 Oct;21(8):575-81.
Sturesson B, Selvik G, Udén A. Movements of the sacroiliac joints. A roentgenstereophotogrammetric analysis (Abstract). Acta Orthop Scand 1988;59(Suppl 227):89.
Söballe K, Toksvig-Larsen S, Gelineck et al. Migration of hydroxyapatite coated femoral prostheses. A roentgen stereophotogrammetric study. J Bone Joint Surg (Br) 1993;75-B:681-7.
Södeqvist I, WedinP-Å. Determining the movements of the skeleton using well-configured markers. Technical note. J Biomechanics 1993;26:1473-77.
Söderqvist I. Some Numerical Methods for Kinematical Analysis. Licentiate of Philosophy. Institute of Information Processing. Department of Computer Science. University of Umeå. UMINF - 186.90. ISSN-0348-0542, 1990.
Saari T, Uvehammer J, Carlsson LV, Herberts P, Regner L, Kärrholm J. Kinematics of three variations of the Freeman-Samuelson total knee prosthesis. Clin Orthop. 2003 May;(410):235-47.
Thanner J, Freij-Larsson C, Kärrholm J, Malchau H, Wesslén B. Evaluation of Boneloc®. Clinical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties. Acta Orthop Scand 1995;66(3):207-214.
Thanner J, Karrholm J, Herberts P, Malchau H. Porous cups with and without hydroxylapatitetricalcium phosphate coating: 23 matched pairs evaluated with radiostereometry.J Arthroplasty 1999 Apr;14(3):266-71
Thanner J, Kärrholm J, Herberts P, Malchau H. Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty. 2000 Jun;15(4):405-12.
Thanner J, Kärrholm J, Malchau H, Wallinder L, Herberts P. Migration of Press-fit Cups Fixed with Poly-L-Lactic Acid or Titanium Screws: A Randomized Study using Radiostereometry. J Orthop Res. 1996;14:895-900
Thanner J. The acetabular component in total hip arthroplasty. Evaluation of different fixation principles. Acta Orthop Scand Suppl. 1999 Aug;286:1-41.
Tjörnstrand B, Selvik G, Egund N, Lindstrand A. Roentgen-stereophotogrammetry in high tibial osteotomy for gonarthrosis. Arch Orthop Trauma Surg 1981;99(2):73-81.
Toksvig-Larsen S, Magyar G, Önsten I, Ryd L, Lindstrand A. Fixation of the tibial component of total knee arthroplasty after high tibial osteotomy. J Bone Joint Surg 1998;80-B:295-297.
Toksvig-Larsen S, Ryd L, Lindstrand A. Early inducible displacement of tibial components in total knee prostheses inserted with and without cement: a randomized study with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am 1998 Jan;80(1):83-9
Toksvig-Larsen S, Ryd L, Lindstrand A. Fixation of the tibial component in knee arthroplasty after six weeks. Int Orthop SICOT 1995;19:89-93.
Tullberg T, Blomberg S, Branth B, Johnsson R. Manipulation does not alter the position of the sacroiliac joint. A roentgen stereophotogrammetric analysis. Spine 1998 May 15;23(10):1124-8; discussion 1129
Uvehammer J, Karrholm J, Brandsson S, Herberts P, Carlsson L, Karlsson J, Regner L. In vivo kinematics of total knee arthroplasty: flat compared with concave tibial joint surface. J Orthop Res 2000 Nov;18(6):856-64
Uvehammer J, Kärrholm J, Brandsson S. In vivo kinematics of total knee arthroplasty. Concave versusposterior-stabilised tibial joint surface. J Bone Joint Surg Br. 2000 May;82(4):499-505.
Uvehammer J, Kärrholm J, Regner L, Carlsson L, Herberts P. Concave versus posterior-stabilized tibial joint surface in total knee arthroplasty: randomized evaluation of 47 knees. J Arthroplasty. 2001 Jan;16(1):25-32.
Uvehammer J, Kärrholm J. Inducible displacements of cemented tibial components during weightbearing and knee extension observations during dynamic radiostereometry related to joint positions and 2 years history of migration in 16 TKR. J Orthop Res. 2001 Nov;19(6):1168-77.
Uvehammer J, Regner L, Kärrholm J. Flat vs. concave tibial joint surface in total knee arthroplasty: randomised evaluation of 39 cases using radiostereometry. Acta Orthop Scand. 2001 Jun;72(3):257-65.
Uvehammer J. Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty. Acta Orthop Scand Suppl. 2001 Feb;72(299):1-52.
Uvehammer J. Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty. Acta Orthop Scand Suppl. 2001 Feb;72(299):1-52.
van Dijk R, Huiskes R, Selvik G. Roentgen-stereophotogrammetric methods for the evaluation of the three-dimensional kinematic behaviour and cruciate ligament length patterns of the human knee joint. J Biomech 1979;12(9):727-31.
van Kampen A, Huiskes R. The three-dimensional tracking pattern of the human patella. J Orthop Res 1990;8(3):372-82.
van Loon CJ, Kyriazopoulos A, Verdonschot N, de Waal Malefijt MC, Huiskes R, Buma P. The role of femoral stem extension in total knee arthroplasty. Clin Orthop. 2000 Sep;(378):282-9.
Walheim G G, Selvik G. Mobility of the pubic symphysis. In vivo measurements with an electromechanic method and a roentgen-stereophotogrammetric method. Clin Orthop 1984;(191):129-35.
Woltring HJ, Huiskes R, De Lange A. Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomechanics 1985;18(5):379-89. Yuan X, Ryd L. Accuracy analysis for RSA: a computer simulation study on 3D marker reconstruction. J Biomech. 2000 Apr;33(4):493-8.
Wykman A, Lundberg A. Subsidence of porous coated noncemented femoral components in total hip arthroplasty: A roentgen stereophotogrammetric analysis. J Arthroplasty 1992;7(2):197-200
Wykman A, Selvik G, Goldie I. Subsidence of the femoral component in the noncemented total hip. A roentgen-stereophotogrammetric analysis. Acta Orthop Scand 1988;59(6):635-7.
Yuan X, Ryd L, Tanner KE, Lidgren L. Roentgen single-plane photogrammetric analysis (RSPA.) A new approach to the study of musculoskeletal movement. J Bone Joint Surg Br. 2002 Aug;84(6):908-14.
Zoëga B, Kärrholm J, Lind B. One-level cervical spine fusion. A randomized study, with or without plate fixation, using radiostereometry in 27 patients. Acta Orthop Scand. 1998;69(4):363-368.
Zoëga B, Kärrholm J, Lind B. Plate fixation adds stability to two-level anterior fusion in the cervical spine: a randomized study using radiostereometry. European Spine Journal. 1998;(7):302-307
Önsten I, Bengnér U, Besjakov J, . Socket migration after Charnley arthroplasty in rheumatoid arthritis and osteoarthritis. A roentgen stereophotogrammetric study. J Bone Joint Surg 1993;75-B:677-80.
Önsten I, Berzins A, Shott S, Sumner DR. Accuracy and precision of radiostereometric analysis in the measurement of THRfemoral component translations: human and canine in vitro models. J Orthop Res. 2001 Nov;19(6):1162-7.
Önsten I, Carlsson Å, Besjakov J. Wear in uncemented porous and cemented polyethylene sockets. J Bone Joint Surg (Br) 1998;80-B:345-350
Önsten I, Carlsson Å, Ohlin A, Nilsson JÅ. Migration of acetabular component inserted with and without cement in one stage bilateral hip arthroplasty. J Bone Joint Surg 1994;76-A:185-194.
Önsten I, Carlsson Å. Cemented vs. uncemented socket in hip arthroplasty. A roentgen stereophotogrammetric study of 60 randomized hips followed for 2 years. Acta Orthop Scand 1994;65:517-21
Önsten I, Nordqvist A, Carlsson ÅS, Besjakov J, Shott S. Hydroxyapatite augumentation of the porous coating improves fixation of tibial component. J Bone Joint Surg 1998;80-B:417-425.
Önsten I, Snorrason F, Borssén B, Kärrholm J, Sandzén L. Uncemented press-fit acetabular prostheses in revision hip arthroplasty. A roentgen stereophotogrammetric analysis (RSA). SOF Trollhättan 1991. Acta Orthop Scand 1991;62(Suppl 246):8, 1991
Önsten I, Åkesson K, Besjakov J, Obrant KJ. Migration of the Charnley stem in rheumatoid arthritis and osteoarthritis. J Bone Jonit Surg 1995;77-B(1):18-22
Östgaard SE, Gottlieb L, Toksvig-Larsen S, Lebech A, Talbot A, Lund B Roentgen stereophotogrammetric analysis using computer-based image-analysis. J Biomech 1997


Web site and all contents © Copyright tantalum-beads.net 2006, All rights reserved.